1 AIA Guidelines for Design and Construction of Health Care Facilities อาจารย อรรณพ ก งขจ Asst. Managing Director EEC Engineering Network ประธานกรรมการว ชาการฯสมาคมปร บอากาศแห งประเทศไทย

2 สถาบ นพ ฒนาและร บรองค ณภาพโรงพยาบาล

3 Joint Commission International (JCI) AIA Guidelines

4 Joint Commission International (JCI) Joint Commission International (JCI) is a division of Joint Commission Resources (JCR), the subsidiary of The Joint Commission. For more than 50 years, The Joint Commission and its predecessor organization have been dedicated to improving the quality and safety of health care services. Today the largest accreditor of health care organizations in the United States, the Joint Commission surveys nearly 20,000 health care programs through a voluntary accreditation process. The Joint Commission and its subsidiary are both not-for-profit corporations.

5 Joint Commission International (JCI)

6 PART Environment of Care *(5) Safety and security. The safety and security of patients or residents, staff, and visitors shall be addressed in the overall planning of the facility consistent with the functional program. *(6) Finishes. The effect of materials, colors, textures, and patterns on patients or residents, staff, and visitors shall be considered in the overall planning and design of the facility.maintenance and performance shall be considered when selecting these items. * อ างอ งข อม ลจากเอกสาร AIA Guideline for Design & Construction of Healthcare Facilities

7 PART Environment of Care *3 Sustainable Design Sustainable design, construction, and maintenance practices to improve building performance shall be considered in the design and renovation of health care facilities.

8 PART Environment of Care *3 Sustainable Design *3.1.1 Site Selection and Development *3.1.2 Waste Minimization *3.1.3 Water Quality and Conservation * Energy Conservation»Proper planning and selection of mechanical and electrical systems, as well as efficient utilization of spaceand climatic characteristics, can significantly reduceoverall energy demand and consumption.

9 PART Planning, Design, and Construction Infection Control Risk Assessment (ICRA) During the planning phase of a project, after considering the facility s patient population and programs, the owner shall provide an infection control risk assessment. An ICRA is a determination of the potential risk of transmission of various air- and waterborne biological contaminants in the facility.

10 Design of Health Care

11 * อ างอ งข อม ลจากโครงการพ ฒนารามาธ บด ส คณะแพทย ศาสตร ช นนาในเอเช ย

12 * อ างอ งข อม ลจากโครงการพ ฒนารามาธ บด ส คณะแพทย ศาสตร ช นนาในเอเช ย

13 PART Planning, Design, and Construction *4 Commissioning 4.1 Mechanical Systems Acceptance criteria for mechanical systems shall be specified Crucial ventilation specifications for air balance and filtration shall be verified before owner acceptance Areas requiring special ventilation (such as surgical services, protective environments, airborne infection isolation rooms, laboratories, and local exhaust systems for hazardous agents) shall be recognized as requiring mechanical systems that ensure infection control. Ventilation deficiencies shall not be accepted Acceptance criteria for local exhaust systems dealing with hazardous agents shall be specified and verified.

14 PART Common Requirements 2.2 Heating, Ventilating, and Air-Conditioning (HVAC) Systems HVAC ductwork (1) General (a) Air-handling duct systems shall be designed with accessibility for duct cleaning and shall meet the requirements of NFPA 90A. (3) Fire and smoke dampers (a) Fire and smoke dampers shall be constructed, located, and installed in accordance with the requirements of NFPA 101, 90A, and the specific damper s listing requirements.

15 PART General Hospitals 3 Nursing Locations Typical Patient Rooms Each patient room shall meet the following standards: Capacity (1) In new construction, the maximum number of beds per room shall be one unless the functional program demonstrates the necessity of a two-bed arrangement. Approval of a two-bed arrangement shall be obtained from the licensing authority.

16 PART General Hospitals Airborne Infection Isolation Room Access to at least one airborne infection isolation room shall be provided unless provided elsewhere in the facility. The number of airborne infection isolation rooms shall be determined on the basis of an infection control risk assessment (ICRA).

17 PART General Hospitals (d) Construction requirements. Operating room perimeter walls, ceiling, and floors, including penetrations, shall be sealed.

18 Drainage systems (1) Piping PART Plumbling (c) Insofar as possible, drainage piping shall not be installed within the ceiling or exposed in operating and delivery rooms, nurseries, food preparation centers, food-serving facilities, food storage areas, central services, electronic data processing areas, electric closets, and other sensitive areas.where exposed overhead drain piping in these areas is unavoidable, special provisions shall be made toprotect the space below from leakage, condensation, or dust particles.

19 PART Plumbling

20 PART Plumbling (2) Floor drains (a) Floor drains shall not be installed in operating and delivery rooms. (3) Autopsy table drain systems. Drain systems for autopsy tables shall be designed to positively avoid splatter or overflow onto floors or back siphonage and for easy cleaning and trap flushing.

21 PART Plumbling Clinical sinks (1) Clinical sinks shall be trimmed with valves that can be operated without hands. Singlelever or wrist blade devices shall be permitted. Handles on clinical sinks shall be at least 6 inches (15.24 centimeters) long. (2) Clinical sinks shall have an integral trap wherein the upper portion of the water trap provides a visible seal.

22 PART HVAC Systems 10.2 Heating, Ventilating, and Air- Conditioning (HVAC) Systems Mechanical system design (1) Efficiency. The mechanical system shall be designed for overall efficiency and appropriate life-cycle cost.

23 Energy Saving & Reliability ( District Energy Center Design ) District Energy Center District Energy Center - Load Sharing Design - Saving Investment - Energy Saving - Operation Cost - Reliability &Stability - Easy Maintenance - Flexible & Support to Siriraj 70 rai - Support Renewable Energy * อ างอ งข อม ลจากโครงการโรงพยาบาลป ยมหาราชการ ณ ( Sirirach Toward Medical Excellence in Southeast Asia)

24

25

26

27 PART HVAC Systems (2) Air-handling systems (b) VAV systems. The energy-saving potential of variable-air-volume systems is recognized, and the standards herein are intended to maximize appropriate use of those systems. Any system used for occupied areas shall include provisions to avoid air stagnation in interior spaces where thermostat demands are met by temperatures of surrounding areas.

28 PART HVAC Systems (c) Noncentral air-handling systems (i.e., individual room units used for heating and cooling purposes, such as fan-coil units, heat pump units, etc.). These units may be used as recirculating units only. All outdoor air requirements shall be met by a separate central air-handling system with proper filtration, as noted in Table

29

30 PART HVAC Systems (3) Temperature and humidity. Space temperature and relative humidity shall be as indicated in Table (4) Air movement direction. To maintain asepsis control, airflow supply and exhaust shall generally be controlled to ensure movement of air from clean to less clean areas, especially in critical areas.

31 Control directional of airflow movement in zone

32 PART HVAC Systems Requirements for Specific Locations Airborne infection isolation rooms. The infectious disease isolation room is used for isolating the airborne spread of infectious diseases, such as measles, varicella, or tuberculosis.

33 Influenza Pandemics in the 20 th Century 1918: Spanish Flu 1957: Asian Flu 1968: Hong Kong Flu million deaths 1 million deaths 1 million deaths H1N1 H2N2 H3N2 ท มา : เอกสารประกอบการบรรยายเร อง ความสาค ญของการควบค มการแพร กระจายเช อโรคทางอากาศในสถานพยาบาล โดย พญ.จร ยา แสงส จจา สถาบ นบาราศนราด ร 13 ต.ค. 2548

34 * อ างอ งข อม ลจากโครงการพ ฒนารามาธ บด ส คณะแพทย ศาสตร ช นนาในเอเช ย

35 PART HVAC Systems (3) Rooms with reversible airflow provisions for the purpose of switching between protective environment and AII functions are not acceptable.

36 PART HVAC Systems Protective environment rooms. The protective environment (PE) room is used to protect the patient from common environmental airborne infectious microbes (i.e., Aspergillus spores). (1) These special ventilation areas shall be designed to provide directed airflow from the cleanest patient care area to less clean areas.

37 INDOOR DESIGN CRITERIA Recirculating Air for OR TA = 30 ACH OA = 5 ACH Patient Room TA >= 12 ACH OA >= 2 ACH Isolation Rooms TA >= 15 ACH (PE) TA >= 12 ACH (AII) OA >= 2 ACH

38 PART HVAC Systems Operating and delivery rooms (1) Air supply (a) In new construction and major renovation work, air supply for operating and delivery rooms shall be from non-aspirating ceiling diffusers with a face velocity in the range of 25 to 35 fpm (0.13 to 0.18 m/s), located at the ceiling above the center of the work area. Return air shall be near the floor level, at a minimum. Return air shall be permitted high on the walls, in addition to the low returns.

39 PART HVAC Systems (b) Each operating and delivery room shall have at least two return-air inlets located as far from each other as practical. (c) Turbulence and other factors of air movement shall be considered to minimize the fall of particulates onto sterile surfaces.

40 รพ.ป ยมหาราชการ ณย คณะแพทย ศาสตร ศ ร ราชพยาบาล Operating Theatre 18 C./55%RH.

41 PART HVAC Systems (3) Ventilation rates *(a) Operating and delivery room ventilation systems shall operate at all times, except during maintenance and conditions requiring shutdown by the building s fire alarm system.

42 PART HVAC Systems HVAC Air Distribution Return air systems. For patient care areas, return air shall be via ducted systems.

43 PART HVAC Systems Filter bed location.where two filter beds are required, filter bed no. 1 shall be located upstream of the air conditioning equipment and filter bed no. 2 shall be downstream of any fan or blowers.

44 PART HVAC Systems Filter manometers. A manometer shall be installed across each filter bed having a required efficiency of 75 percent or more, including hoods requiring HEPA filters. Provisions shall be made to allow access to the manometer for field testing.

45 PART Electrical Systems 10.3 Electrical Systems General Applicable standards All electrical material and equipment, including conductors, controls, and signaling devices, shall be installed in compliance with applicable sections of NFPA 70 and NFPA 99.

46 PART Electrical Systems Panelboards (1) Panelboards serving critical branch, equipment system, or normal system loads shall be located on the same floor as the loads to be served. (3) New panelboards shall not be located in public access corridors.

47 PART Electrical Systems * Hand-washing stations and scrub sinks. If operation of a scrub sink or a handwashing station in critical care areas, emergency departments, labor and delivery, and surgical suites is dependent on the building electrical service, it shall be connected to the essential electrical system.

48 PART Electrical Systems (2) Intermediate care rooms. These shall have at least four duplex outlets per bed. The outlets shall be arranged to provide two duplex outlets on each side of the head of the bed. (3) Critical care areas. As defined by NFPA 99 and NFPA 70, including pediatric and newborn intensive care units, critical care areas shall have at least seven duplex outlets at the head of each bed, crib, or bassinet. Approximately 50 percent of critical care outlets shall be connected to emergency system power and be so labeled.

49 PART Electrical Systems (6) Trauma and resuscitation rooms. These shall have eight duplex outlets located convenient to the head of each bed. (7) Emergency department. Examination and treatment rooms in the emergency department shall have a minimum of six duplex outlets located convenient to the head of each bed. Approximately 50 percent of emergency care outlets shall be connected to emergency system power and be so labeled.

50 PART Electrical Systems Emergency system receptacles. Electrical receptacle cover plates or electrical receptacles supplied from the emergency systems shall be distinctively colored or marked for identification. If color is used for identification purposes, the same color shall be used throughout the facility.

51 LIFE SAFTY SYSTEM

52 The Life Safety Approach Fire/Smoke Compartment Fire Alarm system

53 Voice Evacuation System Staircase Message Please stay calm, be careful with the stairs, help the children and elderly leave the building safety. Evacuation Massage 1 Attention Please. There is an emergency situation in the building. Please evacuate through Exit staircase A. Do not use the lifts. Evacuation Massage (Alarm Floor) Attention Please. There is an emergency situation in the building. Please evacuate through the nearest exit staircase. Do not use the lifts. Evacuation Massage 2 Attention Please. There is an emergency situation in the building. Please evacuate through Exit staircase B. Do not use the lifts. Warning Massage Attention Please. We are investigating an emergency in building. Please remain calm and standby for further instruction. Thank you.

54 AIA Guidelines

55 รพ.ป ยมหาราชการ ณย คณะแพทย ศาสตร ศ ร ราชพยาบาล

56 QUESTION & ANSWER

Ventilation for Healthcare Facilities

Ventilation for Healthcare Facilities Ventilation for Healthcare Facilities Presented to Wisconsin Healthcare Engineering Association November 13, 2014 Need ideas to make this first page interesting; picture? Henneman logo? 1 Topics to be

More information

Ventilation for Healthcare Facilities. Topics to be Covered

Ventilation for Healthcare Facilities. Topics to be Covered Ventilation for Healthcare Facilities Presented to Wisconsin Healthcare Engineering Association November 13, 2014 Need ideas to make this first page interesting; picture? Henneman logo? Topics to be Covered

More information

Interim Life Safety Assessments and Infection Prevention Assessments

Interim Life Safety Assessments and Infection Prevention Assessments Interim Life Safety Assessments and Infection Prevention Assessments 1 Healthcare Construction ILSM and ICRAs PRESENTED BY Bob Dubiel, CHFM, CHC -Mayo Clinic Health System NWWI -Projects and Construction

More information

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY PART I - GENERAL 1.1 SUMMARY A. This section addresses the general requirements for air handling distribution systems, including air handlers, ductwork, ductwork accessories, terminal units, air devices,

More information

Hospital ventilation & infection prevention

Hospital ventilation & infection prevention Hospital ventilation & infection prevention Peter Hoffman Consultant Clinical Scientist Antimicrobial Resistance and Healthcare Infections Reference Unit In the beginning The importance of ingress of contaminated

More information

Prescriptions for Critical Healthcare Cx. John D. Villani, P.E. Associate Grumman/Butkus Associates

Prescriptions for Critical Healthcare Cx. John D. Villani, P.E. Associate Grumman/Butkus Associates Prescriptions for Critical Healthcare Cx John D. Villani, P.E. Associate Grumman/Butkus Associates AIA Quality Assurance Learning Objectives 1. Medical Industry Changes and how they impact Design, Construction,

More information

Create Clean Air. The specialists in Indoor Air Quality

Create Clean Air. The specialists in Indoor Air Quality c r e a t e c l e a n a i r Create Clean Air The specialists in Indoor Air Quality The Air is all around us. It sustains us, Sometimes it restrains us! Create Clean Air We commenced designing systems to

More information

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS By Yuguo Li and SARS Busters * Background The hospital care workers (HCWs) have been the most severely affected professions during the SARS epidemics in

More information

How to comply with CDC Guidelines

How to comply with CDC Guidelines 1101 W. 13th St, Riviera Beach, Florida Phone: 561.848.1826 https://www.rgf.com/rgf-biocontrols How to comply with CDC Guidelines OVERVIEW Sections of text are extracted directly from the Federal Register

More information

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems 233100 AIR DISTRIBUTION PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230700 HVAC Insulation B. Section 237300 Air Handling C. Section 230900 Building Automation and Control System Guidelines D. Section

More information

Theatre Classification and Air Particle Count Is that Surveillance?

Theatre Classification and Air Particle Count Is that Surveillance? Theatre Classification and Air Particle Count Is that Surveillance? Codes and Specifications for Theatre Installations The South African National Standards Wiring Code - SANS 10142-1:2006. Occupational

More information

DUKE CLINIC SITE-SPECIFIC FIRE PLAN Part II General Statement. Fire Procedures

DUKE CLINIC SITE-SPECIFIC FIRE PLAN Part II General Statement. Fire Procedures OCCUPATIONAL AND ENVIRONMENTAL SAFETY OFFICE DUKE CLINIC SITE-SPECIFIC FIRE PLAN Part II General Statement This Department also adheres to the Duke University Safety Manual located at http://www.safety.duke.edu.

More information

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1 Interim Life Safety Measures Purpose of Interim Life Safety Management BASIC SAFETY: During renovations projects in healthcare occupancies, the basic level of protection for the occupants must be maintained

More information

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS Germicidal UV Technology to Inhibit Microbial Growth and Limit Transfer of Infections in Hospitals UVC can be utilized to inhibit microbial growth and transfer in hospitals through installation in HVAC

More information

Element Z General Design Requirements Existing Facilities Information

Element Z General Design Requirements Existing Facilities Information PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G and Element Z for technical

More information

Supplement 3: Engineering Controls

Supplement 3: Engineering Controls Vol. 43 / No. RR-13 MMWR 69 I. Introduction Supplement 3: Engineering Controls This supplement provides information regarding the use of ventilation (Section II) and UVGI (Section III) for preventing the

More information

Fume Hood Safety TYPES OF FUME HOODS

Fume Hood Safety TYPES OF FUME HOODS Fume Hood Safety Fume hoods exhaust toxic, flammable, noxious, or hazardous fumes and vapors by capturing, diluting, and removing these materials. Fume hoods also provide physical protection against fire,

More information

Pharmaceutical Facility Design

Pharmaceutical Facility Design PhEn-602 Pharmaceutical Facility Design J. Manfredi Notes 9A PhEn-602 J. Manfredi 1 Primary & Secondary HVAC units Primary Primary air handling unit arrangement: One unit is responsible for all of the

More information

The Physical Environment Portal: Module 5, LS Leadership

The Physical Environment Portal: Module 5, LS Leadership The Physical Environment Portal: Module 5, LS.02.01.10 - Leadership Fire Safety: Background Fire safety impacts both the lives of the occupants and the physical structures. In the early 1900 s many buildings

More information

INDEX OF VA STANDARD DETAILS AS OF DECEMBER 2014

INDEX OF VA STANDARD DETAILS AS OF DECEMBER 2014 DIVISION 00 SD000115-01 SD000115-02 SD000115-03 SD000115-04 SD000115-05 SD000115-06 SD000115-07 SD000115-08 SD000115-09 SD000115-10 SD000115-11 SD000115-12 SD000115-13 SD000115-14 SD000115-15 SD000115-16

More information

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD. Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes Comparing the Codes: NFPA 101 Life Safety Code (2000) (NFPA) International Building Code (2012) (IBC) Chicago

More information

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of the University of Texas at Austin for safety equipment used in or in support of

More information

PDHengineer.com. Course HV HVAC Design for Hospitals & Healthcare Facilities

PDHengineer.com. Course HV HVAC Design for Hospitals & Healthcare Facilities PDHengineer.com Course HV-6001 HVAC Design for Hospitals & Healthcare Facilities This document is the course text. You may review this material at your leisure before or after you purchase the course.

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH)

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH) FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH) Presented by: Alise Howlett, Assoc. AIA, CFPE, CHFM Standards Advisor, EM/PE/LS HFAP A better healthcare survey experience 1 FREQUENT

More information

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS Presented by: Alise Howlett, Assoc. AIA,CFPE, CHFM Standards Advisor, EM/PE/LS HFAP A better healthcare survey experience 1 FREQUENT PHYSICAL ENVIRONMENT

More information

The Role of Air Handling Units in Combating the Spread of Infectious Disease

The Role of Air Handling Units in Combating the Spread of Infectious Disease The Role of Air Handling Units in Combating the Spread of Infectious Disease Goal To identify those areas within an air handler which poses risk to the healthcare industry and recommended four solutions

More information

Alex Masterton, PE Electrical Engineer Reviewer AHCA Neal Boothe, PE Electrical Engineer/Principal

Alex Masterton, PE Electrical Engineer Reviewer AHCA Neal Boothe, PE Electrical Engineer/Principal Alex Masterton, PE Electrical Engineer Reviewer AHCA Neal Boothe, PE Electrical Engineer/Principal FBC 419.3.15.6 All low-voltage system main or branch circuits entering or exiting the structure shall

More information

Raised Access Floor - (AE Breadth Area)

Raised Access Floor - (AE Breadth Area) Raised Access Floor - (AE Breadth Area) Currently, the Plaza has a raised access flooring system on both the 7 th and 8 th floors. The 8 th floor is designed with an independent HVAC system utilizing an

More information

NORTH CAROLINA. Downloaded (l) For each nursing unit, or fraction thereof on each floor, the following shall be provided:

NORTH CAROLINA. Downloaded (l) For each nursing unit, or fraction thereof on each floor, the following shall be provided: Housekeeping/Laundry/Maintenance NORTH CAROLINA Downloaded 01.15.11 (l) For each nursing unit, or fraction thereof on each floor, the following shall be provided: (3) a soiled utility room with counter,

More information

PDH & Professional Training

PDH & Professional Training 510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 PDH & Professional Training PDH Storm, by Engineers Edge, LLC An Introduction to HVAC Systems for Medical Facilities J. Paul

More information

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS Prepared for the: RPIC/SLCan Sustainable Labs Regional Workshop Presented by: THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY

More information

Technical Report 1. ASHRAE Standards 62.1, 170, and 90.1 Evaluation. Morton Hospital Expansion

Technical Report 1. ASHRAE Standards 62.1, 170, and 90.1 Evaluation. Morton Hospital Expansion Technical Report 1 ASHRAE Standards 62.1, 170, and 90.1 Evaluation Morton Hospital Expansion Taunton, MA Courtney Millett Mechanical Option Advisor: Dr. Bahnfleth September 17, 2014 Millett Technical Report

More information

EC 5.10 FIRE PREVENTION MANAGEMENT

EC 5.10 FIRE PREVENTION MANAGEMENT EC 5.10 FIRE PREVENTION MANAGEMENT The organization manages fire safety risks. 1 The organization develops and maintains a written management plan describing the processes it implements to effectively

More information

PRESSURE RELATIONSHIPS IN HOSPITAL CRITICAL-CARE FACILITIES

PRESSURE RELATIONSHIPS IN HOSPITAL CRITICAL-CARE FACILITIES PRESSURE RELATIONSHIPS IN HOSPITAL CRITICAL-CARE FACILITIES A. J. Streifell, B.B. Bridgesl, D.T. Grimsrudl, B.C. Krafihefer2 luniversitv of Minnesota, USA 2Honeywe~l, Inc. USA ABSTRACT This field study

More information

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN Title/Description: Life Safety & Fire Prevention Management Department: Facilities Management Personnel: All Effective Date: 5/97 Revised: 7/00, 7/01, 7/02, 7/03, 7/04, 7/05, 7/08 LIFE SAFETY & FIRE PREVENTION

More information

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Ventilation for New Low-Rise Residential Buildings July 20, 2015 Ventilation for New Low-Rise Residential Buildings July 20, 2015 BSC Standard 01 2015 Building Science Corporation 3 Lan Drive, Suite 102 Westford, MA 01886 www.buildingscience.com Contents 1. PURPOSE...3

More information

Humane Society of the United States Expo 2017

Humane Society of the United States Expo 2017 info@ Humane Society of the United States Expo 2017 Building Systems: The building systems: mechanical, plumbing, lighting, electrical and noise control systems are critical for success in animal shelter

More information

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai Guidelines for Ideal Layout for an Operating Theater Complex Dr.R.D.Ravindran Aravind Eye Hospital Madurai Patient Flow 1. WARD 4. RECOVERY ROOM 2. BLOCK ROOM 3. THEATRE Transfer area This is an area,

More information

Technical Report Three

Technical Report Three Technical Report Three Existing Conditions for Mechanical Systems Contents Executive Summary...2 Building Overview...2 Mechanical Systems Overview...2 Mechanical System...3 Outdoor & Indoor Design Conditions...3

More information

CENTRAL STATE HOSPITAL PLAN PLANT OPERATIONS UTILITIES MANAGEMENT PLAN

CENTRAL STATE HOSPITAL PLAN PLANT OPERATIONS UTILITIES MANAGEMENT PLAN Page 1 of 11 CENTRAL STATE HOSPITAL PLAN SUBJECT: PLANT OPERATIONS UTILITIES MANAGEMENT PLAN ANNUAL REVIEW MONTH: RESPONSIBLE FOR REVIEW: March CSH Safety Officer LAST REVISION DATE: November 2003 I. SCOPE:

More information

CONNECTICUT. Downloaded

CONNECTICUT. Downloaded Housekeeping/Laundry/Maintenance J. Laundry. CONNECTICUT Downloaded 01.15.11 (1) This service, if provided, shall be used exclusively for laundry and shall be remote from resident and food service areas,

More information

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available. PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the

More information

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1 Table of Contents Page Number(s) Executive Summary 2 Project Background 3 Proposed Depth Alternatives 4 Proposed Depth Redesign 5-7 Justification of Proposed Depth Redesign 8 Proposed Breath Redesign 9

More information

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL SECTION 15100 PART 1 GENERAL THIS IS A DESIGN GUIDE NOT A SPECIFICATION Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL HVAC SYSTEMS APPLICATIONS 1.1 SCOPE: The intent of this

More information

UVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units

UVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units UVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units Part 3: Recirculation UVGI Systems, Zonal Protection Factor, In-place testing Protocols Dr. Wladyslaw Jan Kowalski, PE, Immune Building

More information

Element Z General Design Requirements Existing Facilities Information

Element Z General Design Requirements Existing Facilities Information Charles M. LeMaistre PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G and

More information

Ventilation System Description. September 8, 2000 HETA

Ventilation System Description. September 8, 2000 HETA September 8, 2000 HETA 99-0250 Harry Enoch, Ph.D. Director, Environmental Health and Safety University of Kentucky 252 East Maxwell Street Lexington, KY 40506-0314 Dear Dr. Enoch: On June 7, 1999, the

More information

HGRC have subcommittees

HGRC have subcommittees About This Document Guidelines are developed through a consensus process similar to ANSI. Bringing together members of the Health Guidelines Revision Committee (HGRC) of the Facility Guidelines Institute,

More information

Special Requirements For Health Care Facilities

Special Requirements For Health Care Facilities Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

Building Analytics and Compliance: How analytics can be used to aid in performancebased certifications. Bryant M. Kirkland Jr, PE, CCP, LEED AP

Building Analytics and Compliance: How analytics can be used to aid in performancebased certifications. Bryant M. Kirkland Jr, PE, CCP, LEED AP Building Analytics and Compliance: How analytics can be used to aid in performancebased certifications Bryant M. Kirkland Jr, PE, CCP, LEED AP AIA Quality Assurance The Building Commissioning Association

More information

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 10 Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 2 INDEX Page Description - Introduction -Application - Data... 2 Typical Installation... 3 Sound performance... 3-6 Dimensional

More information

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

ENVIRO UNIT ENGINEERING MANUAL KES SERIES ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units

More information

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS SECTION 11 53 53 BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section

More information

Variable Air Volume with Indoor Air Quality

Variable Air Volume with Indoor Air Quality Variable Air Volume with Indoor Air Quality and a Cure for the Spread of the Airborne Flu Virus January 11, 2017 Dinner Meeting Golden Gate ASHRAE Chapter Presented By: Thomas S. Weaver, P.E., Member ASHRAE

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

4. OVERVIEW OF MECHANICAL SYSTEM

4. OVERVIEW OF MECHANICAL SYSTEM 4. OVERVIEW OF MECHANICAL SYSTEM The 87,000 SF SLCC is served by six (6) Trane M-Series Climate Changer Air Handing Units (AHUs). Each unit serves a distinct zone within the facility that is unique in

More information

DHS Design guidelines for hospitals and day procedure centres. Part E- Building Services and Environmental Design

DHS Design guidelines for hospitals and day procedure centres. Part E- Building Services and Environmental Design 6 HEATING, VENTILATION AND AIR-CONDITIONING Minimum Standards 6. 1.00 The minimum requirements for the provision of heating, ventilation and airconditioning in Health Care Facilities shall be those listed

More information

Appendix A.4.1. Safe Fume Hood User Guide

Appendix A.4.1. Safe Fume Hood User Guide Appendix A.4.1. Safe Fume Hood User Guide Fume hoods are devices designed for work with toxic or hazardous chemicals with the effect of safely capturing the harmful gases, vapors, and fumes generated and

More information

CRITICAL ENVIRONMENTS. Fully Integrated Systems for: Operating Rooms, Isolation Rooms & Pharmacies

CRITICAL ENVIRONMENTS. Fully Integrated Systems for:  Operating Rooms, Isolation Rooms & Pharmacies CRITICAL ENVIRONMENTS healthcaresolutions Fully Integrated Systems for: Operating Rooms, Isolation Rooms & Pharmacies Research Facilities, Process Labs & Pharmaceutical www.price-hvac.com/critical healthcaresolutions

More information

SUBJECT: Effective Date: Procedure Number:

SUBJECT: Effective Date: Procedure Number: SUBJECT: Effective Date: Procedure Number: Facilities Operations/ Utilities and Energy 9/1/2015 FS 2015 UES0002 Services Division of Responsibility Procedure APPLICABILITY/ACCOUNTABILITY: Supersedes: Page

More information

Space Air Diffusion II

Space Air Diffusion II MEBS6008 Environmental Services II http://me.hku.hk/bse/mebs6008/ Space Air Diffusion II Ir. Dr. Sam C. M. Hui Visiting Assistant Professor Department of Mechanical Engineering The University of Hong Kong

More information

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates Issued June 28, 207 Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates Environment of Care (EC) Chapter Nursing Care Center (NCC) Accreditation Program Standard

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning Air Handling Distribution PART 1 - GENERAL 1.01 OVERVIEW A. This section describes criteria for design of facility air handling distribution systems, including air handlers, ductwork, ductwork accessories,

More information

TIPS FOR BETTER JOINT COMMISSION SURVEYS

TIPS FOR BETTER JOINT COMMISSION SURVEYS TIPS FOR BETTER JOINT COMMISSION SURVEYS Washington Society for Healthcare Engineering September 21, 2011 Yakima, Washington The BASICS Most Failed Standards. Scoring. Electronic S. O. C. I.L.S.M. Building

More information

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5 AGENDA: Ambulatory Health Care & Business Occupancies Definitions / Examples Mixed & Contiguous Occupancies Ambulatory Health Care &

More information

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort

More information

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General Requirements

More information

Stephen Panzarino, AIA, NCARB, LEED AP HDR Architecture, Inc. Tampa, FL. Joseph V. Messina, CPD HDR Architecture, Inc. Atlanta, GA

Stephen Panzarino, AIA, NCARB, LEED AP HDR Architecture, Inc. Tampa, FL. Joseph V. Messina, CPD HDR Architecture, Inc. Atlanta, GA Stephen Panzarino, AIA, NCARB, LEED AP HDR Architecture, Inc. Tampa, FL Joseph V. Messina, CPD HDR Architecture, Inc. Atlanta, GA About This Document Guidelines are developed through a consensus process

More information

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING SUMMARY PROVER'S PLAN OF CORRECTION K 000 INITIAL COMMENTS K 000 A Life Safety Code Survey was conducted by the State Fire Marshal beginning on May 9th, 2017 and ending on May 10th, 2017. Adair Acute Care

More information

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance Groton Heights School Mechanical Evaluation TO: FROM: Amy Vaillancourt, Project Manager Harley Langford, Project Manger Jason Curtis, P.E. DATE: February 24, 2016; Revised May 31, 2016 On Monday, December

More information

Element D Services Electrical ODG010107

Element D Services Electrical ODG010107 Element D Services Electrical ODG010107 D5090 Other Electrical Systems Part 1. General This section includes design standards and requirements for other electrical systems. This is a design standard and

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Compliance w/ the 2012 Life Safety Code

Compliance w/ the 2012 Life Safety Code Compliance w/ the 2012 Life Safety Code Implications of the 2012 NFPA Code Set for Existing & New ASCs William E. Lindeman, AIA http://www.weldesigns.com Financial Interest Disclosure The presenter provides

More information

Public Safety in the Healthcare Facility

Public Safety in the Healthcare Facility CABMET Study Group Public Safety in the Healthcare Facility Matt Baretich Baretich Engineering Fort Collins, Colorado mfb@baretich.com Slide 1 Public Safety: 15% of CBET Exam Electrical Chemical Radiation

More information

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize

More information

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION Enjoy Your TJC Survey Bill H. McCully CHFM SASHE Senior Consultant MSL Healthcare Partners PREPARATION 1 Top Eight Most Cited Standards (George Mills) EC News May 2015 Top Citations EC.02.06.01 56% EC.02.05.01

More information

NFPA 99 for Facility Managers

NFPA 99 for Facility Managers NFPA 99 for Facility Managers Application to Existing Facilities October 13, 2015 Jonathan Hart: Senior Fire Protection Engineer Learning Objectives Review the layout of NFPA 99 Understand the application

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. 2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is

More information

Professional Air Decontamination

Professional Air Decontamination Professional Air Decontamination Patient Protection Isolation Wards Critical Areas Are You Aware of the Cost of Healthcare-Associated Infections (HAI)? Of every 100 hospitalized patients, 7 in developed

More information

Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities

Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities 1 Colby Henson Fire Safety Supervisor 665 Mainstream Drive 2nd floor 615-806-4798 Colby.Henson@tn.gov

More information

Biological Safety Cabinets. Biological Safety Cabinets

Biological Safety Cabinets. Biological Safety Cabinets Biological Safety Cabinets Biological Safety Cabinets(BSCs) are among the most effective, as well as the most commonly used primary containment devices in laboratories working with infectious agents. Properly

More information

Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct

Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct LRI TM Lowering Risks by Innovation Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct Prepared for Electro Breeze Air Cleaner Ltd. 117 De L Eglise, St-Sauveur Quebec,

More information

SECTION SPECIAL EXHAUST SYSTEMS. A. Laboratory Ventilation and Hazardous Exhaust Systems. 3. Chemical Fume Hoods and Storage Cabinets

SECTION SPECIAL EXHAUST SYSTEMS. A. Laboratory Ventilation and Hazardous Exhaust Systems. 3. Chemical Fume Hoods and Storage Cabinets SECTION 15852 SPECIAL EXHAUST SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Laboratory Ventilation and Hazardous Exhaust Systems 1. Pre-Design Considerations 2. General Design Criteria 3. Chemical Fume Hoods

More information

Laboratory Fume Cupboards

Laboratory Fume Cupboards Laboratory Fume Cupboards 2006 (d)irene/ /Fumecupboards 4Jun07.doc.doc The University of Hong Kong Safety Office Laboratory Fume Cupboards Table of Content 1. Introduction 2. Components of a Fume Extraction

More information

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

First Aspen Federal Regulation Set: K LSC 2000 Health Existing First Aspen Federal Regulation Set: K 01.01 LSC 2000 Health Existing K 0000 Title CFR Type INITIAL COMMENTS Memo K 0011 If the building has a common wall with a nonconforming building, the common wall

More information

Safe Operating Procedure (Revised 2/10)

Safe Operating Procedure (Revised 2/10) Safe Operating Procedure (Revised 2/10) BIOSAFETY CABINETS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Biosafety Cabinet Classification Biological

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

PENNSYLVANIA. Downloaded

PENNSYLVANIA. Downloaded Housekeeping/Laundry/Maintenance 205.26. Laundry. PENNSYLVANIA Downloaded 01.15.11 (a) A laundry room shall be provided in a facility where commercial laundry service is not used for the washing of soiled

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section

More information

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW... SECTION 230001 TABLE OF CONTENTS SECTION 230001 PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS... 1 1.00 FILED SUB BID... 1 1.01 PROJECT OVERVIEW... 2 1.02 DESIGN CRITERIA... 4 1.03 CODE ISSUES...

More information

SECTION INSPECTION AND TESTING OF WORK

SECTION INSPECTION AND TESTING OF WORK SECTION 01455 PART I - GENERAL 1.01 SECTION INCLUDES A. Project Inspections and Procedures B. Scheduling Inspectors Notification requirements 1.02 RELATED SECTIONS A. Section 01310 COORDINATION B. Section

More information

LABORATORIES, CHEMICAL AND BIOLOGICAL

LABORATORIES, CHEMICAL AND BIOLOGICAL Laboratory Design: Chemical and bio-research laboratories where hazardous materials will be handled or stored shall be designed to safely accommodate the research and/or instruction to be conducted therein.

More information

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following: PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of Sam Houston State University for the design and construction of standpipe systems to include combination standpipe

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

UNIVERSITY OF TOLEDO

UNIVERSITY OF TOLEDO UNIVERSITY OF TOLEDO SUBJECT: INTERIM LIFE SAFETY MEASURES AND INFECTION Procedure No: LS-08-008 CONTROL PROCEDURE STATEMENT Interim life safety and infection control measures will be implemented to protect

More information

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. I. Description Infection Control Manual Policy Name Guidelines for Disposal

More information